Difference between revisions of "Tandberg TDV 1200"
m (added interfaces) |
(added Interfaces section) |
||
| Line 5: | Line 5: | ||
| interface2 = 20 mA current loop | | interface2 = 20 mA current loop | ||
| interface = RS-232C | | interface = RS-232C | ||
| + | | interface3 = RS-422-A (V.11) | ||
}} | }} | ||
The {{PAGENAME}} terminal<ref>{{cite web | The {{PAGENAME}} terminal<ref>{{cite web | ||
| Line 11: | Line 12: | ||
| accessdate=21 April 2012 | | accessdate=21 April 2012 | ||
}}</ref> was produced by Tandberg Data and sold by Norsk Data<ref>[[wikipedia:Norsk Data]]</ref> (ND) as product number 110140. | }}</ref> was produced by Tandberg Data and sold by Norsk Data<ref>[[wikipedia:Norsk Data]]</ref> (ND) as product number 110140. | ||
| + | |||
| + | ==Interfaces== | ||
| + | The terminal has two communication links called "Line A" and "Line B". Each of those can have up to two physical adapters connected (you can only use one at a time). In addition the terminal has a peripheral interface. There is space for up to three optional adapters in the terminal. The standard interface is RS-232-C (V.24) designated "Internal Line A (Ch 4)". | ||
| + | ===Optional adapters=== | ||
| + | *Optional Line A (Ch 3): V.24 (RS-232-C), V.11 (RS-422-A), 20 mA Current Loop, Mouse adapter | ||
| + | *Line B (Ch 1): V.24 (RS-232-C), V.11 (RS-422-A), 20 mA Current Loop, Mouse adapter | ||
| + | *Peripheral interface (Ch 2): Centronics adapter, Magnetic Card Reader adapter | ||
{{References}} | {{References}} | ||
[[Category:Tandberg|TDV 1200]] | [[Category:Tandberg|TDV 1200]] | ||
Revision as of 01:56, 28 August 2012
| Tandberg TDV 1200 | |
|---|---|
| Manufacturer | Tandberg |
| Model | TDV 1200 |
| Communication | |
| Interfaces |
RS-232C, 20 mA current loop, RS-422-A (V.11) |
| Baud Rates | 50 - 38400 |
The Tandberg TDV 1200 terminal[1] was produced by Tandberg Data and sold by Norsk Data[2] (ND) as product number 110140.
Interfaces
The terminal has two communication links called "Line A" and "Line B". Each of those can have up to two physical adapters connected (you can only use one at a time). In addition the terminal has a peripheral interface. There is space for up to three optional adapters in the terminal. The standard interface is RS-232-C (V.24) designated "Internal Line A (Ch 4)".
Optional adapters
- Optional Line A (Ch 3): V.24 (RS-232-C), V.11 (RS-422-A), 20 mA Current Loop, Mouse adapter
- Line B (Ch 1): V.24 (RS-232-C), V.11 (RS-422-A), 20 mA Current Loop, Mouse adapter
- Peripheral interface (Ch 2): Centronics adapter, Magnetic Card Reader adapter
References
- ↑ "Norsk Data Library, document 12.054.1". http://www.sintran.com/sintran/library/libhw/libhw.html. Retrieved 21 April 2012.
- ↑ wikipedia:Norsk Data