Difference between revisions of "CodeChart:Beehive B100"

From Terminals
Jump to: navigation, search
m
m (Category)
 
(10 intermediate revisions by the same user not shown)
Line 1: Line 1:
 +
[[:Special:PrefixIndex/{{FULLPAGENAME}}/|Subpages of {{SUBPAGENAME}}]]
 +
 +
{|
 +
| valign="top" |
 
{{CodeChart
 
{{CodeChart
 +
| title=Received
 
| bel=#bel
 
| bel=#bel
 
| bs=#bs
 
| bs=#bs
Line 6: Line 11:
 
| cr=#cr
 
| cr=#cr
 
| dc1=#DC1
 
| dc1=#DC1
| esc={{FULLPAGENAME}}/ESC
+
| esc=/ESC
 +
}}
 +
| style="width: 2ex;" |
 +
| valign="top" |
 +
{{CodeChart
 +
| title=Transmitted
 +
| esc=/ESC
 
}}
 
}}
 +
|-
 +
| valign="top" |
  
== Control Sequences ==
+
{| class="wikitable"
 +
|+ Control Sequences
 +
{{CodeDescriptionHeader}}
 +
{{CodeDescriptionRow|BEL|bel|Bell}}
 +
{{CodeDescriptionRow|BS|bs|Back Space}}
 +
{{CodeDescriptionRow|HT|ht|Tab}}
 +
{{CodeDescriptionRow|LF|lf|Line Feed}}
 +
{{CodeDescriptionRow|CR|cr|Carriage Return}}
 +
{{CodeDescriptionRow|DC1|dc1|Page Send}}
 +
|}
 +
|}
  
{| style="text-align: center;" border="1"
+
Source: [http://manx.classiccmp.org/details.php/74,18504 B100 Operator's Manual]
! style="padding: 1ex;" | Prefix !! style="padding: 1ex;" | Name !! style="padding: 1ex;" | Parameters
+
 
{{User:Legalize/Control_Sequences/CodeDescriptionTable/Row|Bell||bel|BEL}}
+
[[Category:Code Chart]]
{{User:Legalize/Control_Sequences/CodeDescriptionTable/Row|Back Space||bs|BS}}
 
{{User:Legalize/Control_Sequences/CodeDescriptionTable/Row|Tab||ht|HT}}
 
{{User:Legalize/Control_Sequences/CodeDescriptionTable/Row|Line Feed||lf|LF}}
 
{{User:Legalize/Control_Sequences/CodeDescriptionTable/Row|Carriage Return||cr|CR}}
 
{{User:Legalize/Control_Sequences/CodeDescriptionTable/Row|Page Send||dc1|DC1}}
 
|}
 

Latest revision as of 04:03, 15 January 2014

Subpages of Beehive B100

Received
0 1 2 3 4 5 6 7
0 NUL DLE SP 0 @ P ` p
1 SOH DC1 ! 1 A Q a q
2 STX DC2 " 2 B R b r
3 ETX DC3 # 3 C S c s
4 EOT DC4 $ 4 D T d t
5 ENQ NAQ % 5 E U e u
6 ACK SYN & 6 F V f v
7 BEL ETB ' 7 G W g w
8 BS CAN ( 8 H X h x
9 HT EM ) 9 I Y i y
10 LF SUB * : J Z j z
11 VT ESC + ; K [ k {
12 FF IS4 , < L \ l |
13 CR IS3 - = M ] m }
14 SO IS2 . > N ^ n ~
15 SI IS1 / ? O _ o DEL
Transmitted
0 1 2 3 4 5 6 7
0 NUL DLE SP 0 @ P ` p
1 SOH DC1 ! 1 A Q a q
2 STX DC2 " 2 B R b r
3 ETX DC3 # 3 C S c s
4 EOT DC4 $ 4 D T d t
5 ENQ NAQ % 5 E U e u
6 ACK SYN & 6 F V f v
7 BEL ETB ' 7 G W g w
8 BS CAN ( 8 H X h x
9 HT EM ) 9 I Y i y
10 LF SUB * : J Z j z
11 VT ESC + ; K [ k {
12 FF IS4 , < L \ l |
13 CR IS3 - = M ] m }
14 SO IS2 . > N ^ n ~
15 SI IS1 / ? O _ o DEL
Control Sequences
Prefix Description Parameters
BEL Bell none
BS Back Space none
HT Tab none
LF Line Feed none
CR Carriage Return none
DC1 Page Send none

Source: B100 Operator's Manual